Chemycal Analysis of Inorganic Constituents of Water.
Chemycal Analysis of Inorganic Constituents of Water.
Van Loon, Jon C. Editor.
- Primera Edición.
- 1982
- 248 Páginas Cuadros, figuras 25cm.
TABLE OF CONTENTS
1. Introduction . . . . . 3
Il. Odor . . . . 5
A. Qualitative Test. 6
B. Quantitative Determination . 6
1. Equipment and Reagents . 6
2. Procedure
3. Calculation
4. Notes . . 8
111. Taste
A. Reagents . . . .
B. Procedure . . .10
C. Calculation . . .10
IV. Color . . .10
A. The Visual Comparison Method .11
1. Equipment and Reagents .11
2. Procedure . . . . 1 1
3. Calculation.11
B. The Forel-Ule Scale/Secchi Disc Method .13
V. Turbidity .15
A. The Jackson Turbidimeter Method .18
1. Equipment and Reagents .20
2. Procedure .20
3. Limitations .20
B. The Bottle Standards Comparison Method . .21
C. The Baylis Turbidimetric Method .21
D. The Spectrophotometric (Photoelectric) Turbidimeter Methods .21
1. Equipment and Reagents .25
2. Procedure .25
a. Calibration of Turbidimeter .22
b. Making Turbidity Measurements .26 3. Precision and Accuracy .27
VI. Temperature . . . . . . . .27
A. Mercury Thermometer Immersion Method .28
1. Procedure .28
2. Procedure for Special Cases .28
B. The Reversing Thermometer .29
C. The Mechanical Bathythermograph, MBT .31
1. Procedure . .32
2. Notes . . .33
Vll.
IX. Chemical Analysis of Inorganic Constituents of Water
D. The Electronic Bathythermograph, EBT .33
Procedure .35
The EBT/Rosette Sampler Combination .35
The Sippican@ Expendable Bathythermograph, XBT .35
The Thermistor .38
G. The Infrared Radiation Thermometer .38
pH .39 A. Colorimetric Method
Electrometric Method .42 Equipment and Reagents .43
Procedure
a. pH Meter Calibration
Sample pH Measurement .46
Precision and Accuracy
Notes .47
C. Automated Procedure for pH Measurement .47
Specific Conductance .48
A. Measurement of Specific Conductance .48
Equipment and Reagents .49
Procedure .50 Calculations .51
a. Calculation of Cell Constant .52
Correction for Sample Temperature .52 c. Precision and Accuracy .52
Measurement of Specific Conductance by Automated
Methods .53
Dissolved and Particulate Matter .54
A. Filterable Residue .57
Equipment .57
Procedure .58
Calculation .58
Precision and Accuracy .58
Fixed Filterable Residue .59
Equipment .59
Procedure .59
Calculation .59
Precision and Accuracy .59
C. Nonfilterable Residue .59
Equipment .60
Procedure .60
Calculation .60
Precision and Accuracy .61
D. Fixed Nonfilterable Residue .61
Equipment .61
Procedure .61
Calculation .61
Precision and Accuracy .62
E. Determination of Total Residue, Total Fixed Residue, and Total
0849352096
QUÍMICA INORGÁNICA
R628.161 / C42
TABLE OF CONTENTS
1. Introduction . . . . . 3
Il. Odor . . . . 5
A. Qualitative Test. 6
B. Quantitative Determination . 6
1. Equipment and Reagents . 6
2. Procedure
3. Calculation
4. Notes . . 8
111. Taste
A. Reagents . . . .
B. Procedure . . .10
C. Calculation . . .10
IV. Color . . .10
A. The Visual Comparison Method .11
1. Equipment and Reagents .11
2. Procedure . . . . 1 1
3. Calculation.11
B. The Forel-Ule Scale/Secchi Disc Method .13
V. Turbidity .15
A. The Jackson Turbidimeter Method .18
1. Equipment and Reagents .20
2. Procedure .20
3. Limitations .20
B. The Bottle Standards Comparison Method . .21
C. The Baylis Turbidimetric Method .21
D. The Spectrophotometric (Photoelectric) Turbidimeter Methods .21
1. Equipment and Reagents .25
2. Procedure .25
a. Calibration of Turbidimeter .22
b. Making Turbidity Measurements .26 3. Precision and Accuracy .27
VI. Temperature . . . . . . . .27
A. Mercury Thermometer Immersion Method .28
1. Procedure .28
2. Procedure for Special Cases .28
B. The Reversing Thermometer .29
C. The Mechanical Bathythermograph, MBT .31
1. Procedure . .32
2. Notes . . .33
Vll.
IX. Chemical Analysis of Inorganic Constituents of Water
D. The Electronic Bathythermograph, EBT .33
Procedure .35
The EBT/Rosette Sampler Combination .35
The Sippican@ Expendable Bathythermograph, XBT .35
The Thermistor .38
G. The Infrared Radiation Thermometer .38
pH .39 A. Colorimetric Method
Electrometric Method .42 Equipment and Reagents .43
Procedure
a. pH Meter Calibration
Sample pH Measurement .46
Precision and Accuracy
Notes .47
C. Automated Procedure for pH Measurement .47
Specific Conductance .48
A. Measurement of Specific Conductance .48
Equipment and Reagents .49
Procedure .50 Calculations .51
a. Calculation of Cell Constant .52
Correction for Sample Temperature .52 c. Precision and Accuracy .52
Measurement of Specific Conductance by Automated
Methods .53
Dissolved and Particulate Matter .54
A. Filterable Residue .57
Equipment .57
Procedure .58
Calculation .58
Precision and Accuracy .58
Fixed Filterable Residue .59
Equipment .59
Procedure .59
Calculation .59
Precision and Accuracy .59
C. Nonfilterable Residue .59
Equipment .60
Procedure .60
Calculation .60
Precision and Accuracy .61
D. Fixed Nonfilterable Residue .61
Equipment .61
Procedure .61
Calculation .61
Precision and Accuracy .62
E. Determination of Total Residue, Total Fixed Residue, and Total
0849352096
QUÍMICA INORGÁNICA
R628.161 / C42